MG6 Soft Starter External Bypass Soft Starter
Mg6 general-purpose soft starter is a kind of starting and stopping device which integrates the functions of soft starting, soft stopping, energy saving and multi-protection for motors.
Mg6 general-purpose soft starter is a kind of soft starting, soft stopping, energy-saving and multi-protection function of motor, which is specialized in the starting and stopping device of AC motor. Compared with traditional
Compared with the traditional starting method, after using the Mg6 general-purpose soft starter, the voltage, torque and current on the motor can be smoothly applied and withdrawn.
The voltage, torque and current of the motor can be applied and withdrawn smoothly with the Mg6 general-purpose soft starter, so the problem of mechanical shock of the load will be completely improved.
Meanwhile, it has the communication function with the upper computer control system, which can effectively realize the system networking function.
The high-performance motor algorithms of the Mg6 general-purpose soft starter help to improve the usability, safety and ease of setup of the device.
The high performance motor algorithms of the Mg6 universal soft starter play a significant role in improving the usability, safety and ease of setup of the device.
Mg6 General purpose soft starter
Item | Project Description | |
Standard | GB14048.6-2016(IEC60947-4-2:2011) | |
Applicable motor type | Squirrel-cage three-phase asynchronous motors | |
Motor power | 15A~ 1260A(7.5~630kW) | |
Three-phase power supply | AC380V:50Hz/60Hz±5% | |
Control power supply | AC220V:50Hz/60Hz±5% | |
importation | Allowable Voltage | Continuous voltage fluctuation not more than ±10%, short-term fluctuation not more than 15% to +10% |
fluctuation range | Voltage imbalance rate:<3%;Frequency:±5 | |
Adjustable start time | 1~60s adjustable | |
Adjustable stopping time | 0~60s adjustable | |
I/0 | Logic Inputs | 3 logic inputs (start, stop, emergency stop) |
2 logic inputs (expansion) optional | ||
logical output | 2 relay outputs | |
1 relay output (extension) | ||
4-20mA analog output (expansion) | ||
Run the command by typing | LCD keypad display unit given | |
Control Terminal Setting | ||
Communication protocol (Modbus) optional | ||
485 extranet communication (extension) optional | ||
LCD Chinese display | Display a variety of motor parameters such as current, voltage, alarm, etc. | |
display unit | Key lock and | Realize partial or total locking of keys and define the function range of some keys to |
Function Selection | prevent misoperation | |
Protection and monitoring | Over-voltage, under-voltage, overload, over-temperature, phase loss, over-current and stall protection | |
Indoors, out of direct sunlight, free of dust, corrosive, flammable gases, oil mist, water vapors, dripping water or salts, etc. | ||
Location | ||
matrix | altitude | Altitude over 1000m, should reduce the capacity of use accordingly, every increase of 100m, the current is reduced by 0.5%. |
-10℃+40℃ | ||
Ambient Temperature | Above 40℃, the capacity should be reduced accordingly, and the current will be reduced by 2% for every increase of 1℃. | |
Temperature | Less than 95RH, no water droplet condensation | |
Vibration | Less than 5.9m/s²(0.6g) | |
Storage Temperature | ~40℃~70℃ | |
Protection class | IP20 | |
framework | Cooling method | Radiator, natural cooling |
Installation | Cabinet mounted | |
extended function | Multi-function, I/0 function, analog function, air compressor control, motor monitoring function |
External Bypass Soft Starter Main Features
Starting function
For heavy machinery and equipment has a significant starting effect, so that the motor more smoothly.
Stop function
Effectively solve the mechanical shock and increase the service life of the equipment.
Modularized design
A variety of expandable function modules to meet customers' individual needs, easy to upgrade and maintain the equipment.
Normalized design
Unique product design makes the structure and hardware more reasonable and compact, and effectively solves the problem of space dissipation.
Communication function
Standard configuration of Modbus interface, support customized and various standard bus protocols, easy to realize group control.